SEE Rack Produktportfölj
SEE Rack is a complete unit containing the pumps, heat exchangers, control valves, valves, filters and control logic needed for efficient and safe operation.
SEE Rack is available in different sizes and with a variety of options. The main control logic is integrated into the SEE Rack, it controls all functions and manages all optional add-on products in the installation. The product is a prefabricated unit that replaces the construction of a traditional Cooling distribution centre. It is designed for reliability and SEE-Cooler-S-graph-small.jpghas inherent redundancy while still optimised to use an absolute minimum of energy.
SEE Rack GEO
SEE Rack GEO, optimized for geothermal energy, is the most energy efficient version in the SEE Rack product family.
SEE Rack GEO connects to SEE Coolers, dry coolers, geothermalenergy and electricity as well as maintenance and security systems. The product has built-in redundancy and a power range from 60-750 kW. It achieves COP 73, including geothermic peak load cooling during the summer.
SEE Rack CH-C
A SEE Cooling Concept Solution with Chillers for peak load cooling.
It is available in different sizes and with a variety of options. The drycoolers are in operation for freecooling and in the same drycooler circuit for condencing heat dissipation from the chillers.
SEE Rack CH-C connects to SEE Coolers, dry coolers, chillers and electricity as well as maintenance and security systems. The product has built-in redundancy and a power range from 60-750 kW. It achieves COP 43, excluding peak load cooling during the summer.
SEE Rack CH-D
A SEE Cooling Concept Solution with Chillers for peak load cooling.
It is available in different sizes and with a variety of options. The drycoolers are in operation for freecooling and in a separate drycooler circuit for condencing heat dissipation from the chillers.
SEE Rack CH-D connects to SEE Coolers, dry coolers, chillers and electricity as well as maintenance and security systems. The product has built-in redundancy and a power range from 60-750 kW. It achieves COP 48, excluding peak load cooling during the summer.
SEE Rack HDZ
This rack can be used as a heat exchanger in the coolant circuit next to the High Density Zone to minimize actual coolant volume in sensitive data centers. Comes for one or two coolant circuits.
Optional equipment
Equipment to Recharge ground collectors